Preface |
|
ix | |
The Authors |
|
xi | |
Preface to Second Edition |
|
xiii | |
|
Chapter 1 Overview of Image Production |
|
|
1 | (14) |
|
|
1 | (1) |
|
|
1 | (1) |
|
X-ray beam characteristics |
|
|
2 | (1) |
|
|
3 | (1) |
|
|
3 | (1) |
|
Geometry of image production |
|
|
4 | (5) |
|
|
9 | (1) |
|
|
9 | (1) |
|
Display system and viewing conditions |
|
|
10 | (1) |
|
|
11 | (1) |
|
Practitioner's skill and perception |
|
|
11 | (1) |
|
|
12 | (3) |
|
Chapter 2 Mathematics for Medical Imaging |
|
|
15 | (12) |
|
|
15 | (1) |
|
|
15 | (2) |
|
International system of units |
|
|
17 | (1) |
|
Measurement prefixes (powers) |
|
|
17 | (2) |
|
|
19 | (1) |
|
|
20 | (1) |
|
|
21 | (4) |
|
|
25 | (2) |
|
Chapter 3 Physics for Medical Imaging |
|
|
27 | (22) |
|
|
27 | (1) |
|
|
27 | (7) |
|
|
34 | (5) |
|
Force, work, energy and power |
|
|
39 | (1) |
|
|
39 | (2) |
|
|
41 | (1) |
|
|
42 | (1) |
|
|
42 | (1) |
|
Electricity and electric charge |
|
|
43 | (1) |
|
Electromagnetic radiation |
|
|
44 | (2) |
|
|
46 | (3) |
|
Chapter 4 X-rays, X-ray Tube and X-ray Circuit |
|
|
49 | (24) |
|
|
49 | (1) |
|
|
50 | (1) |
|
|
50 | (5) |
|
|
55 | (1) |
|
The Interaction of high-energy electrons with matter |
|
|
56 | (1) |
|
Interactions between incoming electrons and outer-shell electrons in tungsten |
|
|
56 | (1) |
|
Interactions producing heat |
|
|
57 | (1) |
|
Interactions producing X-rays |
|
|
58 | (1) |
|
Interactions between incoming electrons and inner-shell electrons in tungsten (characteristic X-ray production) |
|
|
58 | (4) |
|
Interactions between incoming electrons and the nucleus of the Atom (Bremsstrahlung X-ray production) |
|
|
62 | (3) |
|
X-ray spectra and factors affecting the quality and intensity of the X-ray beam |
|
|
65 | (1) |
|
Impact of changing the mA |
|
|
66 | (1) |
|
Impact of changing the kV |
|
|
67 | (1) |
|
The impact of filtration on the X-ray beam |
|
|
68 | (3) |
|
|
71 | (2) |
|
Chapter 5 X-ray Interactions in Matter |
|
|
73 | (16) |
|
|
73 | (1) |
|
Interactions of X-rays in matter |
|
|
73 | (4) |
|
The processes of attenuation in diagnostic radiography |
|
|
77 | (1) |
|
|
78 | (1) |
|
|
78 | (1) |
|
|
78 | (5) |
|
|
83 | (4) |
|
|
87 | (2) |
|
Chapter 6 Principles of Radiation Detection and Image Formation |
|
|
89 | (36) |
|
|
89 | (1) |
|
Desirable characteristics of radiation detectors |
|
|
90 | (1) |
|
Detective quantum efficiency |
|
|
90 | (3) |
|
Ionisation chambers used for automatic exposure control circuits |
|
|
93 | (6) |
|
Large field detectors (overview) |
|
|
99 | (1) |
|
Indirect, direct, computed and digital radiography |
|
|
100 | (18) |
|
Digital fluoroscopic systems |
|
|
118 | (3) |
|
|
121 | (4) |
|
|
125 | (14) |
|
|
125 | (1) |
|
|
126 | (2) |
|
Magnification and distortion |
|
|
128 | (1) |
|
|
129 | (1) |
|
|
130 | (1) |
|
|
131 | (1) |
|
Resolution of the imaging system |
|
|
131 | (1) |
|
|
131 | (1) |
|
Measurement of unsharpness in an image |
|
|
132 | (1) |
|
|
132 | (1) |
|
|
132 | (3) |
|
Effect of scatter on contrast |
|
|
135 | (1) |
|
|
136 | (3) |
|
Chapter 8 Radiation Dose and Exposure Indicators |
|
|
139 | (16) |
|
|
139 | (1) |
|
|
140 | (1) |
|
|
141 | (7) |
|
Radiation monitors and personal monitoring |
|
|
148 | (2) |
|
|
150 | (3) |
|
|
153 | (2) |
|
Chapter 9 Image Display and Manipulation in Medical Imaging |
|
|
155 | (20) |
|
|
155 | (1) |
|
|
156 | (3) |
|
|
159 | (1) |
|
|
159 | (4) |
|
Noise reduction by background subtraction |
|
|
163 | (2) |
|
|
165 | (1) |
|
Spatial domain filtering for smoothing and sharpening |
|
|
165 | (2) |
|
Noise reduction by `low-pass spatial filtering' |
|
|
167 | (2) |
|
Image sharpening and edge enhancement `high-pass spatial filtering' |
|
|
169 | (2) |
|
|
171 | (2) |
|
|
173 | (2) |
|
Chapter 10 Computed Tomography |
|
|
175 | (34) |
|
|
175 | (1) |
|
General principles of computed tomography |
|
|
176 | (3) |
|
Creating raw data attenuation values |
|
|
179 | (1) |
|
Creation of data in the xy dimension |
|
|
179 | (11) |
|
Creating data in the z dimension |
|
|
190 | (5) |
|
How does all this relate to scan considerations/protocols |
|
|
195 | (1) |
|
|
195 | (3) |
|
|
198 | (1) |
|
The link between slice thickness, dose, photon density and signal value |
|
|
199 | (4) |
|
Temporal resolution and control of movement |
|
|
203 | (1) |
|
Artefacts and other scan considerations |
|
|
204 | (3) |
|
|
207 | (2) |
|
Chapter 11 Radiation Protection and Safety |
|
|
209 | (18) |
|
|
209 | (1) |
|
|
210 | (5) |
|
|
215 | (1) |
|
Physical, chemical and biological effects of ionising radiation |
|
|
215 | (1) |
|
Cancer effects (stochastic) |
|
|
216 | (2) |
|
Standard operating procedure for women of reproductive capacity |
|
|
218 | (4) |
|
Reporting of radiation incidents |
|
|
222 | (2) |
|
|
224 | (3) |
|
|
227 | (18) |
|
|
227 | (1) |
|
|
227 | (2) |
|
Benefits of examinations using X-rays and gamma photons |
|
|
229 | (1) |
|
Risks from X- and y-Radiation |
|
|
230 | (2) |
|
Possible effects of ionizing radiations on human cells |
|
|
232 | (1) |
|
|
233 | (2) |
|
|
235 | (6) |
|
|
241 | (4) |
Index |
|
245 | |